How to install Gree 5p smallpox machine drainage pipe?

1, smallpox machine's drainage is electric pump drainage. When the water level reaches a certain height, the water pump will start. When it is lower than a certain height, clamp the external water pipe at the joint, and then discharge the drainage pipe to the outside at a certain slope, and keep it straight to avoid unevenness and water accumulation. The insulation pipe will be set outdoors to avoid condensation and dripping.

2. Determine the installation position of the indoor unit of the air conditioner.

The confidential room in the air-conditioning room has a certain distance from the top of the room and the walls on both sides, which is generally greater than 15cm to prevent air circulation resistance. When choosing the location of the indoor unit, we should consider choosing the place where the drainage is easy and the outdoor unit pipeline can be connected; Choose a place where there are no valuables such as TV sets and computers, and the air outlet does not blow directly to the bed.

3. Determine the installation position of the external air conditioner.

Choose the place that maximizes the cooling and heating effect of air conditioning; Minimize adverse effects, such as noise, vibration, condensed water, cold and hot air, etc. Safe, firm and easy to maintain; Avoid direct sunlight, you can choose places such as balconies.

The hole position of the interior wall should be horizontal or slightly lower than the outlet position of the air conditioning drain pipe. The wall hole should be high inside and low outside, and the slope of the wall hole should be 5~ 10 degrees. Before drilling air conditioning holes, be sure to determine the direction of the room circuit to avoid electric shock accidents. Embedded air conditioners are mainly installed in indoor units.

Extended data:

1, according to scientific determination, people will feel more comfortable when the room temperature is generally 25℃-29℃. So when setting the temperature, don't just ask for a low temperature. It is suggested that the temperature difference between indoor and outdoor is 4-5℃. Too high or too low temperature is not conducive to human health, and consumes too much electricity, resulting in unnecessary waste. At the same time, be careful not to change the temperature setting and switch the air conditioner at will.

2. Clean the air filter regularly. The function of the filter screen is to absorb the dust in the air. If there is too much dust, if it is not cleaned in time, it will reduce the air volume, reduce the heat exchange effect, reduce the refrigeration capacity and increase the power consumption. It is more appropriate to clean the filter once every half month. Do not use hot water above 40℃ for cleaning. Do not use washing powder, detergent, gasoline, banana oil, etc. So as to avoid deformation of the filter screen. Don't dry with open flame.

3. Adjust the wind direction correctly. When cooling, the cold air sinks and the wind direction should be horizontal. When heating, the hot air rises, and the wind direction should be vertical downward. In this way, a uniform room temperature effect can be obtained.

4. It is easy for people to feel uncomfortable in air-conditioned rooms for a long time, so it is necessary to open doors and windows for ventilation to reduce the occurrence of air-conditioned diseases.

5. Curtains should be installed in the windows of air-conditioned rooms, especially those facing the sun. At the same time, the room should be sealed as much as possible to reduce the chance of heat entering the room and reduce energy consumption.