How to install radiator water separator?

Is it better to install the radiator with a water separator or not?

There is no need to add moisture to the radiator. There is a method called octopus connection, which uses a water separator. There must be good heating in the community, so that the temperature of each home can be adjusted.

How to decorate the living room with heating water separator

You can make a decorative cabinet to block the water separator, so that the decorative effect of the cabinet is consistent with the whole room. As shown in the figure below:

How to install the hottest radiator?

It is the hottest around the radiator. Generally speaking, it should be a little hotter.

The radiator is not hot, and the location layout of the installation is mainly due to the following reasons.

First, the simplest thing is to close the valve, just open the valve, which is the most common one.

Second, the air in the radiator is not released, which hinders the water flow and makes the radiator unable to dissipate heat. This is also simple. Exhaust air or air through an exhaust valve.

Third, the radiator enters and exits through the pipeline, and the radiator is only hot at the bottom and not hot at the top. There are several possible reasons: 1 The radiator is installed backwards, that is, one end of the radiator is installed on it, and the lower part is open, so all the hot water goes from the lower part. Because there is a water baffle on it, the water flow cannot be exchanged, which leads to the radiator not being hot on it, and some radiators are not hot enough. It's also caused by the water deflector. 2. There is no water baffle, so the water pressure is too high, the barrier between cold water and hot water is broken, and the cold water on it cannot flow back. This is rare. As long as the inlet valve is turned down a little, there should be no problem without a water baffle below, but the heat dissipation is less than the original. There is too much air up there.

Fourth, all the radiators in the house are hot in front and not hot in the back? This will happen if the pipe layout of your home is single pipe in series. As long as the radiator is turned off, nothing else will get hot. If the water inlet temperature is 75 degrees, it will change to 65 degrees or 55 degrees after passing through the first group of water outlets and then enter the second group. The outlet water temperature of the second group will be between 55 and 35 degrees, and finally it will definitely become a radiator that is not hot. The best way to solve this situation is to take the pipeline again and add the circulating pump. There is no other good way. Most of this situation is done by some idiots.

Fifth, the radiators of some parallel pipes are not hot and uneven, mainly because the valves are not properly adjusted and the pipes are not thick enough, so the radiators will not be hot if they fail to meet the standards. Generally, 6 o'clock pipes are enough for rooms below 100 bungalow, but the minimum water flow should reach h/49 kg. 100 100 rpm 180 bungalow needs 1 inch pipe, which has the advantage that the temperature of radiator group and room can be adjusted at will. It was the plumber who asked for adjustment at first. The worst one is that the inner wall of the pipeline will become smaller or blocked during construction, which is impossible to solve.

Sixth, the radiator is definitely not hot up and down, unless it is steam, and the pipeline and radiator riser are vertical, which may cause hot spots. If it is not hot, the principle of not hot is the automatic convection of hot water and cold water. Hot water always rises by itself and cold water sinks automatically, so the radiator is not hot. The solution is to change the pipeline into an upper inlet and a lower outlet, or a lower inlet and a lower outlet.

It should be warmer up there.

How to install radiator water separator

Installation of radiator water separator:

1. Determine the loop number of the water separator as required;

2. Determine the installation position of the oil-water separator according to the system conditions. In general, the installation position should be close to the high entrance of the main pipe. Consideration should also be given to the convenience of installation and maintenance without affecting the installation of the water collector.

3. Before installation, check that the water separator should be a qualified product, check that all valves should be flexible and easy to use, and check whether the filter screen is smooth and free of sundries. Then use a bracket or pipe clamp to fix the water separator firmly;

4. Connect each loop pipeline on the water separator through a water outlet valve and fix it with a pipe clamp;

5, after the completion of the system connection, pressure test, test qualified, installation is complete.

How to connect the radiator and the water separator is better 20 points.

Of course, it is best to connect each group of radiators separately with a water separator. This connection method is called octopus connection, which is the best connection method at present, but it is more expensive.

The connection mode of using tee on the main pipe is called double-pipe parallel connection, which can be divided into double-pipe same journey and double-pipe different journey according to the direction of the pipeline. At present, most of the parallel pipes are double pipes with different paths. The advantage is that the construction is convenient, but the disadvantage is that the water flow regulation is slightly complicated.

Hello, my family has installed a water separator for heating, which consists of floor heating and radiator, but at present, there are only

Thicken the main pipeline, or change a big pump and temporarily turn down the heating, which will heat up when it is cold.

Is it better to install the radiator with a water separator or not?

There is no need to add moisture to the radiator. There is a method called octopus connection, which uses a water separator. There must be good heating in the community, so that the temperature of each home can be adjusted.

Does the radiator need a water separator?

It mainly depends on the number of heaters you have installed. If the quantity is small, there is no need to install a water separator. If the number is large, it is more convenient to install the water separator, which is beneficial to the heating effect!

Installation standard of heating water separator in pipeline well

1, water conveyance system or other industrial water systems also manage several branch pipes, including backwater branch pipe and water supply branch pipe respectively, but their larger positions range from DN350-DN 1500, and they are made of steel plates, which need to be equipped with pressure gauges, thermometers, automatic exhaust valves, safety valves and vent valves. Moreover, a pressure regulating valve needs to be installed between the two containers, and an automatic bypass pipeline is needed for assistance.

2. In the tap water supply system, the use of water separator effectively avoids the loopholes in tap water management, centralizes the installation and management of water meters, and the use of single pipe and multiple channels reduces the procurement cost of pipelines, greatly reduces the construction time and improves the efficiency. Tap water separators are directly connected to the aluminum-plastic main pipeline through different pipe diameters, and water meters are centrally installed in the water meter pool (water meter room) to realize outdoor installation and outdoor inspection. At present, the renovation of family dining tables all over the country is being carried out on a large scale.

How to install your own radiator?

Step 1: First, conduct field measurement and design with the technicians of radiator manufacturers to determine the radiator model, quantity, water inlet and outlet mode and specific installation location. Technicians will determine the radiator model, number of groups, number of each group and installation location according to the actual situation, and sign a radiator purchase and sale contract with the supplier.

Step 2: Sign a construction agreement with the radiator construction unit to ensure the construction quality and risk. Under normal circumstances, the construction unit should indicate in the construction agreement that the heating system is guaranteed for at least one heating season. It is best that the radiator sales unit and the construction unit are the same unit.

Step 3: The first stage of radiator installation. Radiator installation is divided into two steps: the first phase and the second phase. The first-phase heating project includes positioning of heating equipment, slotting, pipeline laying (or pipeline reconstruction), pipeline connection (welded pipe), installation of water collector and separator, pressure test, etc. The second phase of the project includes: radiator installation (radiator fixed suspension, valve connection with radiator and heating pipe), pressure detection of the whole system, radiator debugging, etc.

Step 4: Installation of radiator in the second stage. After the decoration of the customer's home is completed, the second-phase project construction, radiator installation, wood floor installation and other work can only be carried out after the installation is completed and the suppression test is qualified.