Optimal installation position of water separator How to discharge water and exhaust gas from water separator?

Now that winter has arrived, many heating devices have come in handy. In central heating areas in the north, heating is the most common heating device. In the south, if there is no central heating, wall-mounted boilers or floor heating are usually used as heating devices. When installing equipment, there is usually a water separator. So, where is the best installation position of the water separator?

Now that winter has arrived, many heating devices have come in handy. In central heating areas in the north, heating is the most common heating device. In the south, if there is no central heating, wall-mounted boilers or floor heating are usually used as heating devices. When installing equipment, there is usually a water separator. So, where is the water separator installed? How does the water separator discharge water and exhaust air?

installation position of water separator

Generally, the water separator is installed on the wall below the wall-hung boiler, and the position is required to be convenient for operation and sewage discharge. Because there is one outlet and one backwater respectively, they must be staggered by a certain position, which is convenient for the same outlet pipe to match the return pipe. The height should be close to the ground, the installation should be firm and reliable, and it is not easy to be collided and dislocated by other objects. It can also be designed to the bathroom, which is equipped with a waterproof layer. In case of water leakage in the water separator, the water can flow away along the floor drain without harming the innocent. The water separator can also be installed outdoors, so the purpose of installation is mainly to facilitate the later maintenance, such as the balcony of the kitchen, if there is dripping, it can also be discharged through the floor drain.

How to discharge water and exhaust air from the water separator

1. First of all, everyone should prepare the basin and drain pipe. Because when the floor heating separator deflates, there may be water released, and then everyone finds the floor heating separator at home. Generally, the water inlet pipe is above and the water outlet pipe is below.

2. Generally speaking, every water distribution pipe should be deflated, so that the floor heating will work better. When you turn off the main valve first, the floor heating water separator will start to deflate from left to right. When you keep the small water valve of a water distribution pipe still, twist the second to fourth small floor heating water separators 9 degrees to the right, and then turn them off, which means that only one floor heating water separator will deflate.

3. After venting, everyone will start to drain water. You should first connect the prepared plastic pipe to the vent, and then turn the small screw on the vent to the right, so that the water will start to drain.

4. Generally speaking, the water just released is very turbid, and the temperature of the water is relatively low. However, after putting a few pots, the water will gradually become clear, and the temperature will gradually increase. You can obviously feel it with your hands. When the water is discharged from the branch pipe, everyone can close the small water valve, then start to discharge the second pipe, and then discharge the water in turn until it is all.

The article has given you a detailed analysis of the information about where the water separator is installed and how to discharge water and exhaust air. I hope it can help you. When installing the water separator, you must pay attention to the position of the water separator, and you need to discharge water and exhaust air according to the specified process.