Schematic diagram of installation of floor heating water separator

With the cold weather, people began to come up with a magic weapon to keep warm. Heating is very common in northern China, and floor heating, as a very new heating method, has been deeply loved by everyone and widely used, but many friends don't know enough about floor heating. Let's introduce the installation diagram of floor heating water separator to you!

A, floor heating water separator installation diagram

1. Before installing floor heating, some preparations should be made, such as the configuration of materials and the classification of floor heating pipes. If it is central heating, you can choose high-temperature resistant PB pipes, and independent heating is suitable for PERT oxygen-resistant pipes. Conditional water separators can choose intelligent ones. After these, the installation of floor heating is half finished.

2. There are two valves on the two main water pipes, one for water inlet and one for backwater (up and down). These two valves are control switches, which open along the pipeline direction and close perpendicular to the pipeline direction, as shown in the above figure. Closing these two valves is equivalent to closing the whole floor heating system. There are several small valves on the left, which also open along the pipeline direction and close perpendicular to the pipeline direction.

3. The filter is installed in front of the water separator; The connection sequence of the distributor: connect the main water supply pipe-locking valve-filter-ball valve-tee (temperature, pressure gauge and interface)-water separator (upper rod)-geothermal pipe-water collector (lower rod)-ball valve-connect the main return pipe.

Second, the floor heating water separator purchase method

1. Meet the needs of installation and use. When choosing the floor heating water separator, we should first pay attention to the actual installation and use requirements. The current water separator can be mainly divided into stainless steel, copper and other synthetic materials. The characteristics and functions of these materials are very different, and the prices are also very different. The structure of water separator can also be divided into assembly type and welding type. These different types of water separators will have different effects when installed and used because of their different structures. Therefore, it is necessary to pay attention to the selection of suitable materials and types of water separators for installation and use.

2. Because the floor heating water separator needs to bear a certain pressure when working, the requirements for materials are very high, and the copper content of the materials needs to meet the national standards, so as to ensure that there will be no quality problems when installing and using. There is also the need to pay attention to the selection of corrosion-resistant and oxidation-resistant materials. When the water separator works, it may produce some scale or impurities, and the equipment with corrosion-resistant oxidation materials can avoid these problems. Of course, we also need to pay attention to the materials used to connect the valves. The quality of the materials in these details also affects the working efficiency of the water separator.

When you see this, it proves that Bian Xiao's article is drawing to a close. Then, after reading Bian Xiao's installation schematic diagram of the floor heating water separator and the simple skills of the selection method of the floor heating water separator, do you have a general understanding of the floor heating water separator?